EKG / EEG Circuit

How an EKG Readout Is Made Believe it or not, but the human body is full of electrical signals which can be picked up and analyze. These signals come from nerve impulses, which can cause muscle contractions. Voltages range from microvolts (brain waves and some muscle contractions) up to around 2 millivolts p-p (peak-to-peak). Certain conditions or exercise can increase voltages further. Currents tend to be no more than probably a couple microamps or so. Thanks to God's wonderful design of the body, these signals can be picked up and analyzed non-invasively through the use of skin electrodes. Because skin resistance can be high (usually in the mega-ohm range), conductive pastes or gels are often used to make it easier to pick up these signals. Luckily, newer equipment eliminates a lot of mess, due to higher input impedances (input resistance). It is the varying VOLTAGES that are picked up and analyzed. These voltages are amplified greatly (typically by a factor of 1000 X on EKG and around 10,000 X for EEG). The output then can go to a video monitor, paper plotter, radio transmitter, and/or to an analog or digital recording system.



How to Wire Up Thy Neighbors Notes Please note that limb leads ( I, II, III, aVL, aVR, and aVF) do NOT require exact placement. However, better R-waves can be seen when using the limbs as opposed to the chest. However, the chest versions of these leads are more convenient when monitoring for several hours or days at a time. Unless you are doing an EKG for diagnostic reasons, many people would probably oppose the idea of shaving hair off their chests. Also when using limb connections, be sure to place the electrodes over fleshy areas (NOT over bony areas). Please note that the green marks on the drawings represents the ground electrode. The black marks represent the positive electrode. The white marks represents the negative electrode. If you want to do a quickie and use just two electrodes, just short the negative and ground electrodes together. However, this technique does make the output MUCH MORE susceptible to outside interference, such as people walking around (not necessarily the patient).







Modified Chest Lead V1 (MCL1) (or MCL)

This connection is more picky about


Modified Chest Lead V4 (MCL4) This connection is more picky about
the locations of the electrodes.



EKG Amplifier Circuit
the locations of the electrodes.


Safety Notes on Above Circuit First of all, be sure to check your work when building this circuit. I will NOT BE LIABLE for injury or death resulting from the use of this circuit. Built it at your own risk. When I built this circuit using 9-volt batteries for its power, I had a maximum of 7 microamps leaking from any two electrodes. Leakage currents greater than 20 microamps renders such hardware NOT ACCEPTABLE for medical use. Moreover, the medical profession prefers leakage currents to be no more than 10 microamps. Please be aware that some people can begin to feel a shock when even 200-300 microamps are passed through the body. However, be sure to test all three electrode connections (positive to negative, negative to ground, and positive to ground) after building this circuit. Please be aware that maximum leakage currents will vary due to supply voltages, evenness of individual supply voltages, and tolerances of the components themselves. If you have any doubt of any voltage spikes coming out of a computer, oscilloscope, or A/D (analog-to-digital) converter, please add opto-coupling. In order to make this possible, the output of this circuit will need to have 5-9 volts (depending on individual supply voltage) added, and then have a voltage-to-current circuit added. The output of this extra circuit is to then go to an opto-coupler chip. Please be aware that if opto-coupling is used, a small amount of extra programming is required due to the loss of linearity. Probably an exponential function is in order here.





Sitemize Uye Olmadan Linkleri Goremezsiniz. Lutfen Giris Yapin veya Kayit Olun..

07-08-2008 02:37 AM
Web Sayfasını Ziyeret Edin Tüm Mesajlarını Bul Alıntı Yaparak Cevapla
by_zero
Junior Member
**


Mesajlar: 6
Grup Registered
Katılım: Nov 2008
Durum: Çevrimdışı
Rep Gücü: 0
Yas: Belirsiz
Puan: 10
Mesaj: #2
RE: EKG / EEG Circuit

Şekiller ve anlatımı beğendim forum da güzel devamını bekliyorum ve siteyi devamlı takip edeceğim irtibata geçebilrz seni ekledm semih ile başlıor msnim Wink zero felan Big Grin:DBig Grin


Arkadaşım iyi çok güzelde sanırım sende biyomedikal öğrencisisiz öğrendiklerini burada daha geniş paylaşırsan hem sen kazanırsın hemde forum üyeleri ilgin için teşekkür ederm !!!

12-11-2008 12:39 AM
Tüm Mesajlarını Bul Alıntı Yaparak Cevapla
bulutadam
Junior Member
**


Mesajlar: 1
Grup Registered
Katılım: Apr 2009
Durum: Çevrimdışı
Rep Gücü: 0
Yas: Belirsiz
Puan: 2
Mesaj: #3
RE: EKG / EEG Circuit

II numaralı standart bipolar derivasyon, sıklıkla kullanılan bir EKG derivasyonudur. Ölçüm için de günümüzde artık çok maliyetli donanımlar kullanılmaz. En basit şekilde bir PIC veya ATMEL mikrodenetleyici kullanarak, ADC vasıtasıyla dijitalleştirdiğimiz işaretler USART modülleriyle bilgisayarda saklanabilir. Burada ihtiyacımız olan ek donanımlar sadece bir enstrümantasyon kuvvetlendiricisi ve bir kapasite ve direnç'ten oluşan alçak geçiren filtredir. Bu şekilde düşük maliyetlerde EKG ölçüm cihazları yapabilirsiniz...

25-04-2009 12:15 PM
Tüm Mesajlarını Bul Alıntı Yaparak Cevapla
ugurbali
Junior Member
**


Mesajlar: 1
Grup Registered
Katılım: Jan 2010
Durum: Çevrimdışı
Rep Gücü: 0
Yas: Belirsiz
Puan: 3
Mesaj: #4
RE: EKG / EEG Circuit

EKG PAYLAŞIMI ÇOK GÜZEL DE AÇIKLAMALAR NE İNGİLİZCE BİR ANLAM VEREMEDİM

10-01-2010 02:17 AM
Tüm Mesajlarını Bul Alıntı Yaparak Cevapla
ENGiNKOC
Site Kurucusu
********


Mesajlar: 579
Grup Administrators
Katılım: Aug 2008
Durum: Çevrimiçi
Rep Gücü: 0
Yas: 22
Puan: 1432
Mesaj: #5
RE: EKG / EEG Circuit

Paylaştığım içerik bana ait degil. Alıntıdır uğur. Türkçe kaynağım olursa sizlerle paylaşırım.




Sitemize Uye Olmadan Linkleri Goremezsiniz. Lutfen Giris Yapin veya Kayit Olun..

10-01-2010 02:35 AM
Web Sayfasını Ziyeret Edin Tüm Mesajlarını Bul Alıntı Yaparak Cevapla
NESL!
Junior Member
**


Mesajlar: 7
Grup Registered
Katılım: Feb 2010
Durum: Çevrimdışı
Rep Gücü: 0
Yas: 19
Puan: 9
Mesaj: #6
RE: EKG / EEG Circuit

neden ingilzce olarakk anlttn?
çokk taşekkrler tabi bnn yanısıraSmile


nese tmm çokk pardnn alıntıı olduğunuu öğrendmm siteyii daha yeni yenii çözüormm ondandrSmile

07-02-2010 07:38 PM
Tüm Mesajlarını Bul Alıntı Yaparak Cevapla
Cevapla  Konu Gönder 

Yazdırılabilir Bir Sürümü Görüntüle
Bu Konuyu Bir Arkadaşına Gönder
Bu Konuya Üye Ol | Bu Konuyu Favorilerime Ekle

Forumlar Arası Geçişi

Sağlık Bilgileri Web Stats